Strands - Galvanized messengers for telephonic cables



The galvanized strand used as a messenger as support for a figure 8 is covered by means of dipping in a compound sealer. This is done before the plastic cover is placed. The compound is applied to each individual wire while during the braiding process just before being joined. This, in conjunction with the thermoplastic covering guarantees that no moisture will come in contact with the cable. This plastic is applied to the finished strand.

Mechanical Requirements

 

Nominal Diameter of the strand

3/16 inch

¼ inch

Nominal diameter of covered wires, inches (mm)

0,0062 (1,57)

0,080 (2,03)

Minimal resistance of the strand until breakage, Lb (Kg)

3990 (1810)

6650 (3016)

Minimum elongation of the strand in 24 inches (610 mm)%

4,0

4,0

 
Approximate weight per 1000 feet (305 m)

 

Nominal Diameter of the strand

3/16 inch

¼ inch

Prior to dipping
Lb
Kg


73
33


121
55

After dipping
Lb
Kg


75
34


125
57